Nuclear Engineering and Technology (May 2020)

Structural safety reliability of concrete buildings of HTR-PM in accidental double-ended break of hot gas ducts

  • Quanquan Guo,
  • Shaoxu Wang,
  • Shenggang Chen,
  • Yunlong Sun

Journal volume & issue
Vol. 52, no. 5
pp. 1051 – 1065

Abstract

Read online

Safety analysis of nuclear power plant (NPP) especially in accident conditions is a basic and necessary issue for applications and commercialization of reactors. Many previous researches and development works have been conducted. However, most achievements focused on the safety reliability of primary pressure system vessels. Few literatures studied the structural safety of huge concrete structures surrounding primary pressure system, especially for the fourth generation NPP which allows existing of through cracks. In this paper, structural safety reliability of concrete structures of HTR-PM in accidental double-ended break of hot gas ducts was studied by Exceedance Probability Method. It was calculated by Monte Carlo approaches applying numerical simulations by Abaqus. Damage parameters were proposed and used to define the property of concrete, which can perfectly describe the crack state of concrete structures. Calculation results indicated that functional failure determined by deterministic safety analysis was decided by the crack resistance capability of containment buildings, whereas the bearing capacity of concrete structures possess a high safety margin. The failure probability of concrete structures during an accident of double-ended break of hot gas ducts will be 31.18%. Adding the consideration the contingency occurrence probability of the accident, probability of functional failure is sufficiently low. Keywords: Structural safety reliability, Double-ended break, Exceedance probability method, Functional failure probability, HTR-PM