Doklady Belorusskogo gosudarstvennogo universiteta informatiki i radioèlektroniki (Jun 2019)

RADIATION HARDNESS ENSURING OF ANALOG INTEGRATED CIRCUITS

  • O. V. Dvornikov,
  • V. A. Tchekhovski,
  • V. L. Diatlov,
  • YU. V. Bogatyrev,
  • S. B. Lastovski

Journal volume & issue
Vol. 0, no. 4
pp. 105 – 110

Abstract

Read online

Influence of gamma radiation Co60 on static and dynamic characteristics of the transresistance amplifier and the comparator realized on the master slice array «ABMK 1-3» is considered taking into account formulated design rule. At absorbed dose D = 5 Mrad the comparator input current has increased on 25 %, other IC parameters (gain, impulse response of the transresistance amplifier, propagation delay, transition time, output current of the comparator) have changed slightly.