Nuclear Engineering and Technology (Mar 2024)

Assessment of CATHARE code against DEC-A upper head SBLOCA experiments

  • Anis Bousbia Salah

Journal volume & issue
Vol. 56, no. 3
pp. 866 – 872

Abstract

Read online

Design Extension Conditions (DEC)-A assessments of the operating nuclear power plants are generally considered for the purpose of getting additional safety demonstrations of their capability to undergo conditions that are generally more severe than DBAs by features implemented in the design and accident management measures. The pursued methodology is generally based upon Best Estimate approaches aiming at verifying that the safety limits in terms of integrity of the barriers against eventual large or early releases of radioactive material are fulfilled. These aspects are nowadays being experimentally and analytically addressed within the OECD/NEA experimental projects like the ATLAS and PKL series where a set of DEC-A experiments are considered. In this paper, experiments related to SBLOCA at the vessel upper head of the pressurized vessel of ATLAS and PKL are analytically assessed using the CATHARE code. These experiments includes issues related to common cause failure of the safety injection system and operator actions for preventing core excessive overheating. It is shown that, on the one hand, the safety features embedded in the design together with the operator actions are capable to prevent the progression towards a severe accident state and on the other hand, the code prediction capabilities for such scenario are generally good but still to be enhanced.

Keywords