Frontiers in Pediatrics (Jan 2024)

Effects of a valved infant-bottle with ergonomic teat on the coordination of sucking, swallowing, and respiration in late-preterm infants. The Safe Oral Feeding randomized Trial

  • Francesco Cresi,
  • Francesco Cresi,
  • Elena Maggiora,
  • Elena Maggiora,
  • Martina Capitanio,
  • Martina Capitanio,
  • Cecilia Bovio,
  • Federica Borla,
  • Sara Cosimi,
  • Sara Cosimi,
  • Desirèe Enrietti,
  • Desirèe Enrietti,
  • Francesca Faggiano,
  • Sara Loro,
  • Sara Loro,
  • Serena Maria Rovei,
  • Serena Maria Rovei,
  • Federica Runfola,
  • Mariangela Scrufari,
  • Mariangela Scrufari,
  • Michela Vigna Taglianti,
  • Federica Vignali,
  • Federica Vignali,
  • Chiara Peila,
  • Chiara Peila,
  • Alessandra Coscia,
  • Alessandra Coscia

DOI
https://doi.org/10.3389/fped.2024.1309923
Journal volume & issue
Vol. 12

Abstract

Read online

IntroductionBreastfeeding naturally enables the coordination of sucking, swallowing, and respiration patterns for safe feeding. When breastfeeding is not possible a feeding device that releases milk in response to intra-oral vacuum could potentially offer improved coordination of sucking, swallowing, and breathing patterns compared to conventional devices. The aim of the study is to evaluate the effect of a valved infant-bottle with an ergonomic teat compared to a standard infant-bottle.MethodsThis unblinded randomized controlled trial focused on late preterm infants fed by bottle for at least three meals over the day, admitted to the Neonatal Unit of Sant’Anna Hospital (Turin, Italy). Infants were randomized to be fed with a valved infant-bottle with an ergonomic teat (B-EXP arm) or with a standard infant-bottle (B-STD arm). Monitoring included a simultaneous synchronized recording of sucking, swallowing and respiration. The main outcome was the swallowing/breathing ratio.ResultsForty infants (20 B-EXP arm; 20 B-STD arm) with a median gestational age of 35.0 weeks (IQR 35.0–36.0 weeks) completed the study. Four infants were censored for the presence of artifacts in the polygraphic traces. The median swallowing/breathing ratio was 1.11 (1.03–1.23) in the B-EXP arm and 1.75 (1.21–2.06) in the B-STD (p = .003). A lower frequency of swallowing events during the inspiratory phase of breathing was observed in B-EXP arm compared with B-STD arm (p = 0.013).DiscussionThe valved infant-bottle with an ergonomic teat improves the coordination of sucking-swallowing-respiration and limits the risk of inhalation reducing the frequency of swallowing during the inspiratory phase.

Keywords