Neurointervention (Sep 2012)

Endovascular Embolization of Intracranial Aneurysms Using Bare Platinum Axium™ Detachable Coils: Immediate and Short-Term Follow-up Results from a Multicenter Registry

  • Byung Moon Kim,
  • Dong Joon Kim,
  • Pyoung Jeon,
  • Pyung Ho Yoon,
  • Byung Hee Lee,
  • Myeong Sub Lee,
  • Tae Hong Lee,
  • Jun Soo Byun,
  • Dong Ik Kim

DOI
https://doi.org/10.5469/neuroint.2012.7.2.85
Journal volume & issue
Vol. 7, no. 2
pp. 85 – 92

Abstract

Read online

PurposeAxium™ coils were developed to improve the durability of coil-embolized cerebral aneurysms by increasing packing density. The purpose of this prospective multicenter registry was to evaluate the safety and durability of Axium™ coils.Materials and MethodsOne hundred twenty-six patients with 135 aneurysms of ≤ 15 mm in size underwent coil embolization using bare platinum coils, with Axium™ coils constituting over 50% of the total coil length. Immediate and short-term follow-up results were prospectively registered and retrospectively evaluated.ResultsOf the 135 aneurysms (83 unruptured and 52 ruptured), immediate post-embolization angiography revealed complete occlusion in 80 aneurysms (59.3%), neck remnants in 47 (34.8%), and incomplete occlusion in 8 (5.9%). The mean packing density was 42.8% (range, 9.5 - 90%) with Axium™ coil length constituting a mean of 87.9% of total coil length. The rate of procedure-related complications was 16.3%. Procedure-related permanent morbidity and mortality rates were 3.2% and 0.8%, respectively. Follow-up catheter or MR angiography, which was available in 101 aneurysms at 6 - 15 months (mean, 7.7 months), revealed stable or improved occlusion in 95 aneurysms and worsening in 6 aneurysms (5.9%). Lower packing density (< 30%) remained the only predictor for anatomical worsening on multivariable logistic regression analysis (P < 0.05).ConclusionIn this registry, Axium™ coils showed a relatively low rate of anatomical worsening on short-term follow-up imaging with an acceptable periprocedural safety profile compared to reports of other platinum coils. These results may warrant further study of long-term durability with Axium™ coils in larger populations.

Keywords