PLoS ONE (Jan 2021)

Automatic detection of vessel structure by deep learning using intravascular ultrasound images of the coronary arteries.

  • Hiroki Shinohara,
  • Satoshi Kodera,
  • Kota Ninomiya,
  • Mitsuhiko Nakamoto,
  • Susumu Katsushika,
  • Akihito Saito,
  • Shun Minatsuki,
  • Hironobu Kikuchi,
  • Arihiro Kiyosue,
  • Yasutomi Higashikuni,
  • Norifumi Takeda,
  • Katsuhito Fujiu,
  • Jiro Ando,
  • Hiroshi Akazawa,
  • Hiroyuki Morita,
  • Issei Komuro

DOI
https://doi.org/10.1371/journal.pone.0255577
Journal volume & issue
Vol. 16, no. 8
p. e0255577

Abstract

Read online

Intravascular ultrasound (IVUS) is a diagnostic modality used during percutaneous coronary intervention. However, specialist skills are required to interpret IVUS images. To address this issue, we developed a new artificial intelligence (AI) program that categorizes vessel components, including calcification and stents, seen in IVUS images of complex lesions. When developing our AI using U-Net, IVUS images were taken from patients with angina pectoris and were manually segmented into the following categories: lumen area, medial plus plaque area, calcification, and stent. To evaluate our AI's performance, we calculated the classification accuracy of vessel components in IVUS images of vessels with clinically significantly narrowed lumina (< 4 mm2) and those with severe calcification. Additionally, we assessed the correlation between lumen areas in manually-labeled ground truth images and those in AI-predicted images, the mean intersection over union (IoU) of a test set, and the recall score for detecting stent struts in each IVUS image in which a stent was present in the test set. Among 3738 labeled images, 323 were randomly selected for use as a test set. The remaining 3415 images were used for training. The classification accuracies for vessels with significantly narrowed lumina and those with severe calcification were 0.97 and 0.98, respectively. Additionally, there was a significant correlation in the lumen area between the ground truth images and the predicted images (ρ = 0.97, R2 = 0.97, p < 0.001). However, the mean IoU of the test set was 0.66 and the recall score for detecting stent struts was 0.64. Our AI program accurately classified vessels requiring treatment and vessel components, except for stents in IVUS images of complex lesions. AI may be a powerful tool for assisting in the interpretation of IVUS imaging and could promote the popularization of IVUS-guided percutaneous coronary intervention in a clinical setting.