BMC Pediatrics (Oct 2019)
Identifying medication errors in neonatal intensive care units: a two-center study
Abstract
Abstract Background This study aimed to assess the types and frequency of medication errors in our NICUs (neonatal intensive care units). Methods This descriptive cross-sectional study was conducted on two neonatal intensive care units of two hospitals over 3 months. Demographic information, drug information and total number of prescriptions for each neonate were extracted from medical records and assessed. Results A total of 688 prescriptions for 44 types of drugs were checked for the assessment of medical records of 155 neonates. There were 509 medication errors, averaging (SD) 3.38 (+/− 5.49) errors per patient. Collectively, 116 neonates (74.8%) experienced at least one medication error. Term neonates and preterm neonates experienced 125 and 384 medication errors, respectively. The most frequent medication errors were wrong dosage by physicians in prescription phase [WU1] (142 errors; 28%) and not administering medication by nurse in administration phase (146 errors; 29%). Of total 688 prescriptions, 127 errors were recorded. In this regard, lack of time and/or date of order were the most common errors. Conclusions The most frequent medication errors were wrong dosage and not administering the medication to patient, and on the quality of prescribing, lack of time and/or date of order was the most frequent one. Medication errors happened more frequently in preterm neonates (P < 0.001). We think that using computerized physician order entry (CPOE) system and increasing the nurse-to-patient ratio can reduce the possibility of medication errors.
Keywords