Pamukkale University Journal of Engineering Sciences (Oct 2016)

Design of 6 switched 3-level inverter with RL load

  • Ali Saygın,
  • Alper Kerem

Journal volume & issue
Vol. 22, no. 5
pp. 349 – 352

Abstract

Read online

In this study, an alternative topology to multilevel inverter topologies is given. 6 IGBT seminconductor switches are used in this topology and coupled inductors are used in the output stage of the inverter. Using coupled inductors voltages, the 6 switched 3-level inverter has been obtained. In the simulation study, Proportional Integral (PI) controller has been used. By using the data taken from controller, the required switching signals have been produced for a 6 switched 3-level inverter. These signals have been taken by using space vector pulse width modulation technique. Using Computer Aided Design (CAD) analysis a RL load that have 10 Ω and 0.2 H values is simulated and inverter performance has been investigated.