Underground Space (Dec 2024)
Seismic and vibration control of segmented isolation layer in underground structure-diaphragm wall system
Abstract
In this paper, a seismic and vibration reduction measure of subway station is developed by setting a segmented isolation layer between the sidewall of structure and the diaphragm wall. The segmented isolation layer consists of a rigid layer and a flexible layer. The rigid layer is installed at the joint section between the structural sidewall and slab, and the flexible layer is installed at the remaining sections. A diaphragm wall-segmented isolation layer-subway station structure system is constructed. Seismic and vibration control performance of the diaphragm wall-segmented isolation layer-subway station structure system is evaluated by the detailed numerical analysis. Firstly, a three-dimensional nonlinear time-history analysis is carried out to study the seismic response of the station structure by considering the effect of different earthquake motions and stiffness of segmented isolation layer. Subsequently, the vibration response of site under training loading is also studied by considering the influence of different train velocities and stiffness of the segmented isolation layer. Numerical results demonstrate that the diaphragm wall-segmented isolation layer-subway station structure system can not only effectively reduce the lateral deformation of station structure, but also reduce the tensile damage of the roof slab. On the other hand, the developed reduction measure can also significantly reduce the vertical peak displacements of site under training loading.