Clinical Ophthalmology (Jul 2022)

Efficacy of a Secondary Trifocal Sulcus IOL in Providing Near and Intermediate Vision in Patients with Prior Myopic Laser Vision Correction and Cataract Surgery

  • Gundersen KG,
  • Gjerdrum B,
  • Potvin R

Journal volume & issue
Vol. Volume 16
pp. 2219 – 2226

Abstract

Read online

Kjell Gunnar Gundersen,1 Bjørn Gjerdrum,1 Richard Potvin2 1iFocus Øyeklinikk AS, Haugesund, Norway; 2Science in Vision, Bend, OR, USACorrespondence: Kjell Gunnar Gundersen, iFocus Øyeklinikk AS, Sørhauggata 111, Haugesund, 5527, Norway, Tel +47 808900, Email [email protected]: To evaluate the visual function of patients with a history of prior laser vision correction and cataract surgery with implantation of a monofocal primary IOL after subsequent implantation of a secondary sulcus trifocal intraocular lens (IOL).Setting: One clinical practice in Haugesund, Norway.Design: Prospective, single arm, non-interventional unmasked study.Methods: Eligible subjects who had previous laser vision correction and cataract surgery involving implantation of a monofocal IOL in the capsular bag of one or both eyes were subsequently implanted with a secondary IOL in the sulcus. Postoperative uncorrected and best distance-corrected visual acuities (VAs) were measured at distance (4 m), intermediate (60 cm), and near (40 cm), along with low contrast visual acuity and the monocular distance corrected defocus curve.Results: Twenty-five eyes were evaluated from 7 to 24 months after trifocal implantation. The mean monocular uncorrected VAs were 0.06, 0.21 and 0.10 logMAR at distance, intermediate and near, respectively. Uncorrected near VA was 0.2 logMAR or better in 80% of eyes (20/25). VA of 0.2 logMAR or better at all test distances was achieved in 15/25 eyes (60%) in the uncorrected state and 17/25 eyes (68%) when corrected for distance vision. Binocular uncorrected distance visual acuity was 0.1 logMAR or better in all subjects while binocular uncorrected near visual acuity was 0.1 logMAR or better in all but one subject. The defocus curve showed a range of functional vision from distance to 30 cm. No adverse events were identified.Conclusion: The trifocal sulcus IOL provided excellent distance and near vision and a good range of functional vision, similar to results obtained when a primary trifocal IOL is implanted. It is a viable option to provide better intermediate and near vision to patients with a prior history of refractive surgery and a monofocal IOL implanted.Keywords: LASIK surgery, post-LASIK cataract surgery, trifocal IOL, intraocular lens, sulcus IOL, secondary IOL, 1stQ AddOn®

Keywords