Arthroplasty Today (Aug 2021)

A Workflow Change in Anterior Approach Total Hip Arthroplasty Leads to Improved Accuracy of Biomechanical Reconstruction Without Increased Risk of Complications

  • Stephanie V. Kaszuba, MD,
  • Kyle M. Behrens, MD,
  • Chad B. Anderson, PA-C,
  • Alexander C. Gordon, MD

Journal volume & issue
Vol. 10
pp. 99 – 104

Abstract

Read online

Background: During anterior approach total hip arthroplasty (THA), the femur may be an impediment for acetabular access, pushing reamers proximally and consequently altering the hip center. In an effort to address this, the senior author changed the surgical workflow from acetabulum first (AF) to femur first (FF). The objective of this study was to compare the precision of biomechanical hip reconstruction and clinical outcomes between the FF and AF techniques. Methods: This is a retrospective, case-control study of 267 anterior THAs (132 AF and 135 FF). A normal, contralateral hip was used to determine the native biomechanical parameters. Using a calibrated software program, radiographic measurements were performed to calculate the hip center position, femoral offset, global offset, and leg length of the operative and native hips using 2-week postoperative anteroposterior pelvis radiographs. Demographics, operative information, hemoglobin change, and complication data were obtained. Functional outcomes were assessed with the Hip Dysfunction and Osteoarthritis Outcome Score for Joint Replacement survey at 1 year postoperatively. Results: The groups exhibited similar demographic characteristics. The FF group demonstrated significantly more accurate and more precise reconstruction of horizontal and vertical hip centers, femoral offset, and leg length. There was no significant difference in operative time, hemoglobin change, complication rate, or Hip Disability and Osteoarthritis Outcome Score, Joint Replacement scores between groups. Conclusions: The FF technique allowed for more accurate and precise reconstruction of the hip center, leg length, and offset in THA than the AF workflow. Furthermore, the FF approach demonstrated no significant differences in complication rate or blood loss, nor in clinical outcomes. Level of Evidence: Therapeutic Study Level III.

Keywords