Malaysian Orthopaedic Journal (Nov 2020)
A Novel Technique for Fixation of Non-union Unicondylar Hoffa’s Fracture: A Case Report
Abstract
Hoffa fractures are rare and difficult fractures to manage. Hoffa fracture involves a coronal plane fracture of posterior femoral condyle. Non-union in Hoffa fracture is further difficult to manage. The surgical management for such nonunion includes open reduction with recon/LCP plate or screw fixation with bone grafting. The problem with plates is the difficulty in contouring the plates according to the shape of posterior femoral condyles. We describe a new technique with 2 L shaped neutralisation plates placed in a circular fashion. This technique provides a more rigid construct and gives better holding strength of screws in Hoffa fragment. This enhances union and mobilisation can be started early.