Applied Sciences (Apr 2022)
Flow Analysis of PM/NO<sub>X</sub> Aftertreatment System for Emergency Generator
Abstract
Emergency generators normally use diesel engines. The generators need to conduct weekly no-load operation inspections to ensure stable performance in emergency situations. In particular, the generators with large diesel engines mainly use rectangle-type filter substrates. To minimize hazardous emissions generated by generators, optimizing the reduction efficiency through computational fluid dynamics (CFD) analysis of flow characteristics of particulate matter (PM)/NOX reduction system is important. In this study, we analyzed internal flow by CFD, which is difficult to confirm by experimental method. The main factors in our numerical study are the changes of flow uniformity and back pressure. As a result, the flow distribution characteristics according to the cross-sectional shape are similar at high engine loads. Spraying urea in the reverse direction increases static pressure, greatly improving flow uniformity. Raising the selective catalyst reduction (SCR) diffuser angle to 30 degrees improves both back pressure and flow uniformity characteristics, and when the porosity increases, both flow uniformity and back pressure decrease.
Keywords