Nuclear Materials and Energy (Sep 2021)
A method for high heat flux fatigue test of W/Cu/steel small mock-up using normal cooling conditions
Abstract
Fatigue property of W/steel joints is important for predicting the life of First Wall (FW). Few facilities can satisfy the harsh coolant parameters of FW. It is necessary to develop a method to evaluate the fatigue property, using coolant with normal pressure and temperature, for example 0.2 MPa and 25 ℃. Combining numerical calculation and experiment validation. Building the relationship between different heat flux and the maximum temperature and strain, predicting the life of FW according to Manson-Coffin formula (MC). Verifying by the fatigue test in a High Heat Flux test platform equipped with an electron gun, the experimental results have shown the feasibility of this method.