Radiology and Oncology (May 2020)

The influence of shielding reinforcement in a vault with limited dimensions on the neutron dose equivalent in vicinity of medical electron linear accelerator

  • Ivkovic Ana,
  • Faj Dario,
  • Kasabasic Mladen,
  • Sovilj Marina Poje,
  • Krpan Ivana,
  • Branilovic Marina Grabar,
  • Brkic Hrvoje

DOI
https://doi.org/10.2478/raon-2020-0024
Journal volume & issue
Vol. 54, no. 2
pp. 247 – 252

Abstract

Read online

High energy electron linear accelerators (LINACs) producing photon beams with energies higher than 10 MeV are widely used in radiation therapy. In these beams, fast neutrons are generated, which results in undesired contamination of the therapeutic beam. In this study, measurements and Monte Carlo (MC) simulations were used to obtain neutron spectra and dose equivalents in vicinity of linear accelerator.

Keywords