BMC Musculoskeletal Disorders (Jan 2024)

Metal interference screw fixation combinations show high revision rates in primary hamstring tendon ACL reconstruction

  • Janina Kaarre,
  • Neilen A. Benvegnu,
  • Ian D. Engler,
  • Ehab M. Nazzal,
  • Bálint Zsidai,
  • Eric Hamrin Senorski,
  • Volker Musahl,
  • Kristian Samuelsson

DOI
https://doi.org/10.1186/s12891-023-07109-y
Journal volume & issue
Vol. 25, no. 1
pp. 1 – 8

Abstract

Read online

Abstract Background Different fixation methods in anterior cruciate ligament reconstruction (ACLR) have been associated with different revision rates, specifically in the early postoperative period. However, most previous research has either grouped together different fixation types or evaluated femoral-sided fixation or tibial-sided fixation separately. Therefore, the purpose of this study was to determine ACL revision rates for specific combinations of femoral and tibial fixation methods within 2 years of primary hamstring tendon autograft ACLR based on data from the Swedish National Knee Ligament Registry (SNKLR). Methods Patients that underwent primary hamstring tendon autograft ACLR between 2005 and 2018 in the SNKLR were included. The collected data included patient characteristics (age, sex, body mass index [BMI]), activity at time of injury, surgical information (concomitant injuries, time from injury to surgery, fixation types at the femur and tibia), and subsequent revision ACLR. Revision rate within 2 years of the index procedure was chosen, as ACLR fixation is most likely to contribute to ACLR revision within the first 2 years, during graft maturation. Results Of the 23,238 included patients undergoing primary hamstring ACLR, 581 (2.5%) underwent revision ACLR within 2 years of the index procedure. Among the combinations used for > 300 patients, the femoral metal interference screw/tibial metal interference screw fixation combination had the highest revision rate followed by metal interference screw/resorbable screw and Endobutton/AO screw fixation combinations, with respective revision rates of 4.0, 3.0, and 3.0%. The lowest revision rate within 2 years of ACLR was found in the Endobutton/metal interference screw with backup Osteosuture fixation combination, used in 433 cases, with a failure rate of 0.9%. Conclusion Different early ACL revision rates were found across different combinations of femoral and tibial fixation devices within 2 years of primary hamstring tendon autograft ACLR. Metal interference screw fixation, particularly when performed on both the femoral and tibial sides, most frequently resulted in revision ACLR. These findings may be helpful for surgeons in selecting appropriate fixation devices for hamstring ACLR. Level of evidence IV

Keywords