Journal of Clinical and Translational Science (Mar 2021)

44190 Comparing the Accuracy of Different Tools in Identifying Glaucoma Medication Non-adherence

  • Juno Cho,
  • Leslie Niziol,
  • Paul Lee,
  • Michele Heisler,
  • Kenneth Resnicow,
  • David C Musch,
  • Paula Anne Newman-Casey

DOI
https://doi.org/10.1017/cts.2021.725
Journal volume & issue
Vol. 5
pp. 127 – 127

Abstract

Read online

ABSTRACT IMPACT: Medication non-adherence is a widespread problem in glaucoma care, and this abstract shows that a free and easy to implement tool can be used to accurately screen and identify patients who are not adherent to their glaucoma medication. OBJECTIVES/GOALS: To compare the accuracy of pharmacy refill data and five measures of self-reported adherence in identifying patients with poor electronically monitored glaucoma medication adherence. METHODS/STUDY POPULATION: Glaucoma patients (age ≥40, poor self-reported adherence, and ≥1 medication) recruited at the University of Michigan completed five surveys of adherence and 3-months of electronically monitored medication adherence; pharmacy refill data were obtained. Electronically monitored adherence was summarized monthly as percent of doses taken on time. Median monthly adherence ≤80% was considered non-adherent. Pharmacy refill data were reported as the proportion of days covered. The accuracy of the measures in predicting ≤80% adherence was assessed with receiver operating characteristic curves such as estimation of area under the curve (AUC), sensitivity, specificity, and accuracy. RESULTS/ANTICIPATED RESULTS: 95 patients completed electronic monitoring with a median monthly adherence of 74% (±21%); 53 patients (56%) were non-adherent. Pharmacy refill adherence was not significantly correlated with electronically monitored medication adherence (r=0.12, p=0.2). A single-item adherence question (‘Over the past month, what percentage of your drops do you think you took correctly?’) had the largest correlation with electronically monitored adherence (r=0.47, p<0.0001), the largest AUC for predicting non-adherence (AUC= 0.76, [95% Confidence Interval = 0.66, 0.87]), best accuracy (71%, [61, 82]), and good sensitivity (84%, [73, 96]). DISCUSSION/SIGNIFICANCE OF FINDINGS: A free, single-item screening question ('Over the past month, what percentage of your drops do you think you took correctly?') offers an easy-to-implement tool for identifying glaucoma patients with poor medication adherence in clinical practice.