Sensors (Oct 2023)

Is Running Power a Useful Metric? Quantifying Training Intensity and Aerobic Fitness Using Stryd Running Power Near the Maximal Lactate Steady State

  • Cody R. van Rassel,
  • Oluwatimilehin O. Ajayi,
  • Kate M. Sales,
  • James K. Griffiths,
  • Jared R. Fletcher,
  • W. Brent Edwards,
  • Martin J. MacInnis

DOI
https://doi.org/10.3390/s23218729
Journal volume & issue
Vol. 23, no. 21
p. 8729

Abstract

Read online

We sought to determine the utility of Stryd, a commercially available inertial measurement unit, to quantify running intensity and aerobic fitness. Fifteen (eight male, seven female) runners (age = 30.2 [4.3] years; V·O2max = 54.5 [6.5] ml·kg−1·min−1) performed moderate- and heavy-intensity step transitions, an incremental exercise test, and constant-speed running trials to establish the maximal lactate steady state (MLSS). Stryd running power stability, sensitivity, and reliability were evaluated near the MLSS. Stryd running power was also compared to running speed, V·O2, and metabolic power measures to estimate running mechanical efficiency (EFF) and to determine the efficacy of using Stryd to delineate exercise intensities, quantify aerobic fitness, and estimate running economy (RE). Stryd running power was strongly associated with V·O2 (R2 = 0.84; p 2 = 0.91; p 2 = 0.79; p 2 = 0.08; p = 0.313). Measures of running EFF near the MLSS were not different across intensities (~21%; p > 0.05). In conclusion, although Stryd could not quantify RE in isolation, it provided a stable, sensitive, and reliable metric that can estimate aerobic fitness, delineate exercise intensities, and approximate the metabolic requirements of running near the MLSS.

Keywords