Advances in Materials Science and Engineering (Jan 2016)
Long-Span Wooden Structural Floors with Self-Tensioning System: Performance under Asymmetrical Loads
Abstract
This study analyzes the performance of wooden structural floors equipped with the self-tensioning system patented by the authors, consisting of a force multiplying mechanism connected to a self-tensioning tendon, which is activated automatically when the load is applied to the structural element. The paper describes the system’s difficulties when the structural floor is subjected to asymmetrical loads. The proposed solution consists of anchoring the tendon by an adhesive connection in the central part of the piece yielding a favorable redistribution of the bending moments and an effective performance in terms of deformations. The comparative study focuses on π-shape cross section pieces with spans of 12 m and 15 m, using sections without prestressing and with initial prestressing and self-tensioning system.