Cancer Imaging (Mar 2023)

The diagnostic value of contrast-enhanced ultrasonography in breast ductal abnormalities

  • Bo Wang,
  • Di Yang,
  • Xuan Zhang,
  • XuanTong Gong,
  • Tong Xu,
  • Jie Han,
  • YinPeng Ren,
  • ShuangMei Zou,
  • Lin Li,
  • Yong Wang

DOI
https://doi.org/10.1186/s40644-023-00539-w
Journal volume & issue
Vol. 23, no. 1
pp. 1 – 12

Abstract

Read online

Abstract Background Ductal lesions are an important, often overlooked, and poorly understood issue in breast imaging, which have a risk of underlying malignancy ranging from 5 to 23%. Ultrasonography (US), which has largely replaced galactography or ductography, has become an important imaging method to assess patients with ductal lesions. However, it is difficult to distinguish benign from malignant ductal abnormalities only by ultrasonography, most of which are recommended to be at least in subcategory 4A; these require biopsy according to the ACR BI-RADS®atlas 5th Edition-breast ultrasound. Contrast-enhanced ultrasound (CEUS) has been shown to be valuable for differentiating benign from malignant tumors, but its value is unclear in breast ductal lesions. Therefore, the purposes of this study were to explore the characteristics of malignant ductal abnormalities on US and CEUS imaging and the diagnostic value of CEUS in breast ductal abnormalities. Methods Overall, 82 patients with 82 suspicious ductal lesions were recruited for this prospective study. They were divided into benign and malignant groups according to the pathological results. Morphologic features and quantitative parameters of US and CEUS were analyzed by comparison and multivariate logistic regression to determine the independent risk factors. The diagnostic performance was assessed by receiver operating characteristic (ROC) curve analysis. Results Shape, margin, inner echo, size, microcalcification and blood flow classification on US, wash-in time, enhancement intensity, enhancement mode, enhancement scope, blood perfusion defects, peripheral high enhancement and boundary on CEUS were identified as features correlated with malignant ductal lesions. However, multivariate logistic regression showed that only microcalcification (OR = 8.96, P = 0.047) and enhancement scope (enlarged, OR = 27.42, P = 0.018) were independent risk factors for predicting malignant ductal lesions. The sensitivity, specificity, positive predictive value, negative predictive value, accuracy and area under the ROC curve of microcalcifications combined with an enlarged enhancement scope were 0.895, 0.886, 0.872, 0.907, 0.890, and 0.92, respectively. Conclusions Microcalcification and enlarged enhancement scope are independent factors for predicting malignant ductal lesions. The combined diagnosis can greatly improve the diagnostic performance, indicating that CEUS can be useful in the differentiation of benign and malignant lesions to formulate more appropriate management for ductal lesions.

Keywords