Water (Feb 2022)

Efficacies of Nitrogen Removal and Comparisons of Microbial Communities in Full-Scale (Pre-Anoxic Systems) Municipal Water Resource Recovery Facilities at Low and High COD:TN Ratios

  • Supaporn Phanwilai,
  • Pongsak (Lek) Noophan,
  • Chi-Wang Li,
  • Kwang-Ho Choo

DOI
https://doi.org/10.3390/w14050720
Journal volume & issue
Vol. 14, no. 5
p. 720

Abstract

Read online

At a low COD:TN ratio (≤5) in influent, maintaining a longer HRT (≥9 h) and longer SRT (≥30 d) are suggested to improve higher N removal efficiency in case of operation at low DO (Dissolved oxygen) level (0.9 ± 0.2 mg-O2/L). However, in case of operation at high DO level (4.0 ± 0.5 mg-O2/L), short HRT (1 h) and typical SRT (17 d) make it possible to achieve nitrogen removal. On the other hand, at a high COD:TN ratio (≥8.4), a typical HRT (9–15 h), SRT (12–19 d), and DO level (1.3–2.6 mg-O2/L) would be applied. Microbial distribution analysis showed an abundance of AOA (Ammonia-oxidizing archaea) under conditions of low DO (≤0.9 mg-O2/L). Nitrosomonas sp. are mostly found in the all investigated water resource recovery facilities (WRRFs). Nitrosospira sp. are only found under operating conditions of longer SRT for WRRFs with a low COD:TN ratio. In comparison between abundances of Nitrobacter sp. and Nitrospira sp., abundances of Nitrobacter sp. are proportional to low DO concentration rather than abundance of Nitrospira sp. A predominance of nosZ-type denitrifiers were found at low DO level. Abundance of denitrifiers by using nirS genes showed an over-abundance of denitrifiers by using nirK genes at low and high COD:TN ratios.

Keywords