EPJ Web of Conferences (Jan 2024)

Preliminary analysis of TREAT free-field experiments using OpenMC

  • Ferney Paul,
  • Holschuh Tommy,
  • Chipman Andrew,
  • Jensen Colby

DOI
https://doi.org/10.1051/epjconf/202430213003
Journal volume & issue
Vol. 302
p. 13003

Abstract

Read online

This work analyses activation calculations for dosimetry materials during a steady-state irradiation in the Transient Reactor Test (TREAT) reactor core. Hence, we developed a workflow based on the Monte Carlo code OpenMC alongside a custom depletion solver. The irradiation-induced activity as a function of time is computed, and several sensitivity studies are performed to evaluate uncertainty. This study has shown activity computations are sensitive to flux amplitude, irradiation time, atoms quantity and microscopic cross sections. Stochastic uncertainties have been propagated to evaluate the activity uncertainty for each dosimetry material. Most uncertainties are below our target of 3%, which demonstrates OpenMC as a powerful predictive and analysis tool. The precise results obtained through this newly developed computation scheme will be used in future experiments to characterize quantities of interest when operating the TREAT reactor in new configurations.