BMC Veterinary Research (Mar 2019)

A European interlaboratory trial to evaluate the performance of different PCR methods for Mycoplasma bovis diagnosis

  • Henk J. Wisselink,
  • Bregtje Smid,
  • Jane Plater,
  • Anne Ridley,
  • Anna-Maria Andersson,
  • Anna Aspán,
  • Tarja Pohjanvirta,
  • Nella Vähänikkilä,
  • Helene Larsen,
  • Jonas Høgberg,
  • Adélie Colin,
  • Florence Tardy

DOI
https://doi.org/10.1186/s12917-019-1819-7
Journal volume & issue
Vol. 15, no. 1
pp. 1 – 12

Abstract

Read online

Abstract Background Several species-specific PCR assays, based on a variety of target genes are currently used in the diagnosis of Mycoplasma bovis infections in cattle herds with respiratory diseases and/or mastitis. With this diversity of methods, and the development of new methods and formats, regular performance comparisons are required to ascertain diagnostic quality. The present study compares PCR methods that are currently used in six national veterinary institutes across Europe. Three different sample panels were compiled and analysed to assess the analytical specificity, analytical sensitivity and comparability of the different PCR methods. The results were also compared, when appropriate, to those obtained through isolation by culture. The sensitivity and comparability panels were composed of samples from bronchoalveolar fluids of veal calves, artificially contaminated or naturally infected, and hence the comparison of the different methods included the whole workflow from DNA extraction to PCR analysis. Results The participating laboratories used i) five different DNA extraction methods, ii) seven different real-time and/or end-point PCRs targeting four different genes and iii) six different real-time PCR platforms. Only one commercial kit was assessed; all other PCR assays were in-house tests adapted from published methods. The analytical specificity of the different PCR methods was comparable except for one laboratory where Mycoplasma agalactiae was tested positive. Frequently, weak-positive results with Ct values between 37 and 40 were obtained for non-target Mycoplasma strains. The limit of detection (LOD) varied from 10 to 103 CFU/ml to 103 and 106 CFU/ml for the real-time and end-point assays, respectively. Cultures were also shown to detect concentrations down to 102 CFU/ml. Although Ct values showed considerable variation with naturally infected samples, both between laboratories and tests, the final result interpretation of the samples (positive versus negative) was essentially the same between the different laboratories. Conclusion With a few exceptions, all methods used routinely in the participating laboratories showed comparable performance, which assures the quality of diagnosis, despite the multiplicity of the methods.

Keywords