Scientific Reports (Nov 2023)

Liquid resistivity of pharmaceutical propellants using novel resistivity cell

  • Hussein Ahmad,
  • Manoochehr Rasekh,
  • Nadarajah Manivannan,
  • Wamadeva Balachandran

DOI
https://doi.org/10.1038/s41598-023-45253-6
Journal volume & issue
Vol. 13, no. 1
pp. 1 – 13

Abstract

Read online

Abstract Metered-dose inhalers employ propellants to produce pharmaceutical aerosols for treating respiratory conditions like asthma. In the liquid phase, the DC volume resistivity of pharmaceutical propellants, including R134a, R152a, and R227ea, was studied at saturation pressures and room temperature (not vapour phase). These measurements are essential for industries like refrigerants. Aerosols from metered dose inhalers (MDIs) with these propellants become electrically charged, affecting medicament deposition in lung. The resistivity was measured using a novel concentric cylinder-type capacitance cell designed in-house. The resistivity for the propellants (R134a, R152a, and R227ea) was found to be 3.02 × 1010 Ωm, 2.37 × 109 Ωm and 1.31 × 1010 Ωm, respectively. The electrical resistivity data obtained was found to be at least two orders of magnitude higher than the limited data available in the literature. Challenges in the resistivity cell’s development and performance are discussed, with a focus on various propellants and their mixtures with ethanol and moisture concentrations. The resistivity of propellant mixtures containing moisture concentrations ranging from 5 to 500 ppm and ethanol concentrations ranging between 1000 and 125,000 ppm was determined. The resistivity was tested across 10-min and 1-h periods and was performed in accordance with the contemporary IEC 60247 standard.