Science and Technology of Nuclear Installations (Jan 2018)

Strategy Evaluation for Cavity Flooding during an ESBO Initiated Severe Accident

  • Nan Jiang,
  • Minjun Peng,
  • Wei Wei,
  • Tenglong Cong

DOI
https://doi.org/10.1155/2018/8680406
Journal volume & issue
Vol. 2018

Abstract

Read online

Intentional depressurization and cavity flooding are two important measures in current severe accident management guidelines (SAMGs). An extreme scenario of an extended station blackout (ESBO), when electric power is unavailable for more than 24 hours, actually occurred in the Fukushima Daiichi accident and attracted lots of attention. In an ESBO, the containment spray cannot be activated for condensation, and, thus, cavity flooding will generate a large amount of steam, which, ironically, overpressurizes the containment to failure before the reactor vessel is melted through. Therefore, consideration of these conflicting issues and the ways in which plants operate is crucial for strengthening the strategies outlined in SAMGs. In this paper, the effects of intentional depressurization and cavity flooding in an ESBO for a representative 900 MW second-generation pressurized water reactor (PWR) are simulated with MAAP4 code. Diverse scenarios with different starting times of depressurization and water injection are also compared to summarize the positive and negative impacts for accident mitigation. The phenomena associated with creep ruptures, hydrogen combustion, corium stratification, and cavity boiling are also analyzed in detail to strengthen our understanding of severe accident mechanisms. The results point out the facility limitations of second-generation PWRs which can improve existing SAMGs.