Bio-Protocol (May 2015)

Chlorophyll Fluorescence Measurements in Arabidopsis Plants Using a Pulse-amplitude-modulated (PAM) Fluorometer

  • Reiko Motohashi,
  • Fumiyoshi Myouga

DOI
https://doi.org/10.21769/BioProtoc.1464
Journal volume & issue
Vol. 5, no. 9

Abstract

Read online

In this protocol, to analyze PSII activity in photosynthesis, we measure the Fv/Fm (Fv=Fm ± Fo) value (Fo and Fm are the minimum and maximum values of chlorophyll fluorescence of dark-adapted leaves, respectively). Fv/Fm is a reliable marker of photo- inhibition (Krause et al., 1988). Chlorophyll fluorescence in leaves was measured at room temperature using a photosynthesis yield analyzer (MINI- PAM, Walz, Effeltrich, Germany) and a pulse-amplitude-modulated (PAM) fluorometer (TEACHING-PAM, Walz, Effeltrich, Germany).