A Light-Powered Micropump with Dynamic Collective Behavior for Reparation
Yunyu Sun,
Hao Wang,
Jiwei Jiang,
Hui Zhang,
Limei Liu,
Keying Zhang,
Bo Song,
Bin Dong
Affiliations
Yunyu Sun
Institute of Functional Nano & Soft Materials (FUNSOM), Jiangsu Key Laboratory for Carbon-Based Functional Materials & Devices, Soochow University, Suzhou 215123, China
Hao Wang
Institute of Functional Nano & Soft Materials (FUNSOM), Jiangsu Key Laboratory for Carbon-Based Functional Materials & Devices, Soochow University, Suzhou 215123, China
Jiwei Jiang
Institute of Functional Nano & Soft Materials (FUNSOM), Jiangsu Key Laboratory for Carbon-Based Functional Materials & Devices, Soochow University, Suzhou 215123, China
Hui Zhang
Institute of Functional Nano & Soft Materials (FUNSOM), Jiangsu Key Laboratory for Carbon-Based Functional Materials & Devices, Soochow University, Suzhou 215123, China
Limei Liu
College of Mechanical Engineering, Yangzhou University, Yangzhou 225127, China
Keying Zhang
Anhui Key Laboratory of Spin Electron and Nanomaterials of Anhui Higher Education Institutes, School of Chemistry and Chemical Engineering, Suzhou University, Suzhou 234000, China
Bo Song
Laboratory of Advanced Optoelectronic Materials, College of Chemistry, Chemical Engineering and Materials Science, Soochow University, Suzhou 215123, China
Bin Dong
Institute of Functional Nano & Soft Materials (FUNSOM), Jiangsu Key Laboratory for Carbon-Based Functional Materials & Devices, Soochow University, Suzhou 215123, China
Inspired by the collective behaviors of active systems in nature, the collective behavior of micromotors has attracted more and more attention in recent years. However, little attention has been paid to the collective behavior of the immobilized micromotor, i.e., the micropump. In this paper, a unique pentacene-based micropump is reported, which demonstrates dynamic collective behavior activated by white light irradiation. The light irradiation may generate the photochemical reactions between pentacene and water, leading to the electroosmotic flow. As a result, this micropump is capable of pumping the surrounding solution inward along the substrate surface based on the electroosmosis mechanism. Intriguingly, the inward pumping causes the agglomeration of the tracer particles on the surface of the micropump. In addition, the aggregation can migrate following the change in the light irradiation position between two adjacent micropumps. Based on the aggregating and migrating behaviors of this pentacene-based micropump, we have achieved the conductivity restoration of the cracked circuit.