Vestnik of Vitebsk State Technological University (Aug 2020)

Modernization of Convective Heating Surface of Water Boilers

  • Sergey Kuzmenkov,
  • Vasiliy Dryukov,
  • Alexej Kotow,
  • Uladzimir Mausesian

DOI
https://doi.org/10.24411/2079-7958-2020-13805
Journal volume & issue
Vol. 1, no. 38
pp. 52 – 58

Abstract

Read online

The research object is the convective heating surface of water boilers. The purpose of the work is heat engineering design calculation of the options for upgrading the convective heating surface of the KVGM-100 boilers. As a result of the calculations performed according to the proposed methodology, it is revealed that replacing smooth pipes with an outer diameter of 28 mm in the convective bundle of the KVGM-100 boiler unit with finned tubes with an outer diameter of 38 mm can increase the density of the transmitted heat flux by 30 times. Such heat transfer efficiency in a convective beam will increase the efficiency of the boiler as a whole and, consequently, reduce the boiler fuel consumption. Объектом исследований является конвективная поверхность нагрева водогрейных котлов. Целью работы является теплотехнический проектировочный расчет вариантов модернизации конвективной поверхности нагрева водогрейных котлов КВГМ-100. В результате выполненных расчетов по предложенной методике показано, что замена в конвективном пучке котельного агрегата КВГМ-100 гладких труб наружным диаметром 28 мм на оребренные трубы наружным диаметром 38 мм позволяет повысить плотность передаваемого теплового потока в 30 раз. Такая эффективность теплообмена в конвективном пучке обеспечит повышение КПД котла в целом и, следовательно, снижение потребления топлива котельной.

Keywords