Pharmaceutics (Feb 2021)

Evaluation of Binders in Twin-Screw Wet Granulation

  • Claudia Köster,
  • Sebastian Pohl,
  • Peter Kleinebudde

DOI
https://doi.org/10.3390/pharmaceutics13020241
Journal volume & issue
Vol. 13, no. 2
p. 241

Abstract

Read online

The binders povidone (Kollidon 30), copovidone (Kollidon VA64), hypromellose (Pharmacoat 606), and three types of hyprolose (HPC SSL-SFP, HPC SSL, and HPC SL-FP) were evaluated regarding their suitability in twin-screw wet granulation. Six mixtures of lactose and binder as well as lactose without binder were twin-screw granulated with demineralized water at different barrel fill levels and subsequently tableted. A screening run with HPC SSL determined the amount of water as an influential parameter for oversized agglomerates. Subsequent examination of different binders, especially Kollidon 30 and Kollidon VA64 resulted in large granules. All binders, except Pharmacoat 606, led to a reduction of fines compared to granulation without a binder. The molecular weight of applied hyproloses did not appear as influential. Tableting required an upstream sieving step to remove overlarge granules. Tableting was possible for all formulations at sufficient compression pressure. Most binders resulted in comparable tensile strengths, while Pharmacoat 606 led to lower and lactose without a binder to the lowest tensile strength. Tablets without a binder disintegrated easily, whereas binder containing tablets of sufficient tensile strength often nearly failed or failed the disintegration test. Especially tablets containing Pharmacoat 606 and HPC SL-FP disintegrated too slowly.

Keywords