Sensors (Apr 2024)
Mind the Exit Pupil Gap: Revisiting the Intrinsics of a Standard Plenoptic Camera
Abstract
Among the common applications of plenoptic cameras are depth reconstruction and post-shot refocusing. These require a calibration relating the camera-side light field to that of the scene. Numerous methods with this goal have been developed based on thin lens models for the plenoptic camera’s main lens and microlenses. Our work addresses the often-overlooked role of the main lens exit pupil in these models, specifically in the decoding process of standard plenoptic camera (SPC) images. We formally deduce the connection between the refocusing distance and the resampling parameter for the decoded light field and provide an analysis of the errors that arise when the exit pupil is not considered. In addition, previous work is revisited with respect to the exit pupil’s role, and all theoretical results are validated through a ray tracing-based simulation. With the public release of the evaluated SPC designs alongside our simulation and experimental data, we aim to contribute to a more accurate and nuanced understanding of plenoptic camera optics.
Keywords