CVIR Endovascular (Jun 2021)

Accuracy of registration techniques and vascular imaging modalities in fusion imaging for aortic endovascular interventions: a phantom study

  • M. M. Sieren,
  • C. Schareck,
  • M. Kaschwich,
  • M. Horn,
  • F. Matysiak,
  • E. Stahlberg,
  • F. Wegner,
  • T. H. Oechtering,
  • J. Barkhausen,
  • J. Goltz

DOI
https://doi.org/10.1186/s42155-021-00234-6
Journal volume & issue
Vol. 4, no. 1
pp. 1 – 10

Abstract

Read online

Abstract Background This study aimed to assess the error of different registration techniques and imaging modalities for fusion imaging of the aorta in a standardized setting using a anthropomorphic body phantom. Materials and methods A phantom with the 3D printed vasculature of a patient suffering from an infrarenal aortic aneurysm was constructed. Pulsatile flow was generated via an external pump. CTA/MRA of the phantom was performed, and a virtual 3D vascular model was computed. Subsequently, fusion imaging was performed employing 3D-3D and 2D-3D registration techniques. Accuracy of the registration was evaluated from 7 right/left anterior oblique c-arm angulations using the agreement of centerlines and landmarks between the phantom vessels and the virtual 3D virtual vascular model. Differences between imaging modalities were assessed in a head-to-head comparison based on centerline deviation. Statistics included the comparison of means ± standard deviations, student’s t-test, Bland-Altman analysis, and intraclass correlation coefficient for intra- and inter-reader analysis. Results 3D-3D registration was superior to 2D-3D registration, with the highest mean centerline deviation being 1.67 ± 0.24 mm compared to 4.47 ± 0.92 mm. The highest absolute deviation was 3.25 mm for 3D-3D and 6.25 mm for 2D-3D registration. Differences for all angulations between registration techniques reached statistical significance. A decrease in registration accuracy was observed for c-arm angulations beyond 30° right anterior oblique/left anterior oblique. All landmarks (100%) were correctly positioned using 3D-3D registration compared to 81% using 2D-3D registration. Differences in accuracy between CT and MRI were acceptably small. Intra- and inter-reader reliability was excellent. Conclusion In the realm of registration techniques, the 3D-3D method proved more accurate than did the 2D-3D method. Based on our data, the use of 2D-3D registration for interventions with high registration quality requirements (e.g., fenestrated aortic repair procedures) cannot be fully recommended. Regarding imaging modalities, CTA and MRA can be used equivalently.

Keywords