BMC Pulmonary Medicine (Dec 2019)

Dynamics of microbiota during mechanical ventilation in aspiration pneumonia

  • Ken Otsuji,
  • Kazumasa Fukuda,
  • Midori Ogawa,
  • Yoshihisa Fujino,
  • Masayuki Kamochi,
  • Mitsumasa Saito

DOI
https://doi.org/10.1186/s12890-019-1021-5
Journal volume & issue
Vol. 19, no. 1
pp. 1 – 12

Abstract

Read online

Abstract Background The emergence of multi-drug resistant pathogens is an urgent health-related problem, and the appropriate use of antibiotics is imperative. It is often difficult to identify the causative bacteria in patients with aspiration pneumonia because tracheal aspirate contains contaminants of oral bacteria. We investigated the dynamics of microbiota in mechanically ventilated patients with aspiration pneumonia to develop a treatment strategy. Methods Twenty-two intubated patients with aspiration pneumonia were recruited. Saliva and tracheal aspirate of the subjects were collected at three time points: (A) within 2 h after intubation, (B) just before administration of antibiotics, and (C) 48-72 h after administration of antibiotics. The microbiota in each specimen was analyzed by using the 16S rRNA gene clone library sequencing method. Bacterial floras of the samples were analyzed by principal component analysis. Results Principal component analysis based on the composition of genus revealed that although the changes of microbiota in the saliva from (A) to (B) were not clear, the composition of anaerobes in the tracheal aspirate (B) was lower than (A). In fact, the reduction of anaerobes, not in the saliva but in the tracheal aspirate from (A) to (B), was confirmed by incident rate ratios estimated by a multilevel Poisson regression model (p < 0.001). The extent of decrease in anaerobes was fully dependent on the time difference between the sampling of tracheal aspirate (A) and (B)—in particular, over 3 h of mechanical ventilation. This indicates that the alterations of microbiota (involving the reduction of anaerobes in the lower respiratory tract) occurred during mechanical ventilation prior to the administration of antibiotics. After the administration of antibiotics, Enterobacter spp., Corynebacterium spp., Pseudomonas aeruginosa, Klebsiella pneumoniae, Staphylococcus aureus, and Granulicatera adiacens were predominantly detected in the tracheal aspirate (C). Conclusion The microbiota of the lower respiratory tract changes dynamically during mechanical ventilation and during the administration of antibiotics in intubated patients with aspiration pneumonia. Antibiotics should be selected on the premise that dynamic changes in microbiota (involved in the reduction of anaerobes) may occur during the mechanical ventilation in these patients.

Keywords