JA Clinical Reports (Oct 2024)
Dynamic shunt flow alterations through patent foramen ovale during off-pump coronary artery bypass grafting induced by airway pressure changes: a case report
Abstract
Abstract Background Interatrial right-to-left shunt flow through a patent foramen ovale (PFO) can be caused by changes in heart position for anastomosis during off-pump coronary artery bypass (OPCAB). We herein present a case in which the direction of PFO shunt flow changed with heart position during OPCAB and the ventilation settings after sternal closure. Case presentation A 66-year-old man with interstitial pneumonia underwent OPCAB. Preoperative transesophageal echocardiography revealed right-to-left shunt flow through a PFO induced by the Valsalva maneuver. During OPCAB, heart displacement resulted in right-to-left shunting and acute hypoxemia, which quickly improved with increase of inspired oxygen fraction. After chest closure, bidirectional shunt flow developed under increased airway pressure. Conclusions Vigilant intraoperative monitoring with TEE and postoperative airway pressure management are important to address shunt flow and hypoxemia due to PFO.
Keywords