Reviews in Analytical Chemistry (Nov 2011)

Covalent grafting of three flavonoids onto the glassy carbon electrode surface by cyclic voltammetry

  • Mülazımoğlu Ïbrahim Ender,
  • Üstündağ Zafer,
  • Özkan Erdal,
  • Solak Ali Osman

DOI
https://doi.org/10.1515/REVAC.2011.105
Journal volume & issue
Vol. 30, no. 3-4
pp. 177 – 185

Abstract

Read online

Electrochemical oxidation of quercetin (QR), 3-hydroxy­flavone (3HF), and baicalein (BN) and their grafting onto the glassy carbon (GC) electrode have been studied using the cyclic voltammetric (CV) technique. Electrochemical studies were performed within a one-compartment three-electrode cell at room temperature. The modification was carried out only in nonaqueous media, while the electrochemical characterization was done in both aqueous and nonaqueous media. In the nonaqueous experiments, 0.1 m tetrabutylammonium tetrafluoroborate in acetonitrile was used, whereas in the aqueous experiments, Britton-Robinson buffer solutions (pH=2) and 0.1 m KCl solutions were. Surface modifications were performed by CV for all compounds. The presence of QR, 3HF, and BN at the GC electrode surface was characterized by CV, electrochemical impedance spectroscopy, contact angle measurement, ellipsometry, and atomic force microscopy.

Keywords