مجله علوم و فنون هسته‌ای (Sep 2023)

Investigation of effective parameters in increasing the confinement time of electrons in a low beta Polywell device

  • M. Bagheri,,
  • A. Salar Elahi,
  • M.K. Salem,
  • M. Ghoranneviss

DOI
https://doi.org/10.24200/nst.2022.1136.1748
Journal volume & issue
Vol. 44, no. 3
pp. 38 – 48

Abstract

Read online

In a polywell reactor, it is critical to have a stable and energetic virtual cathode that is necessary to accelerate ions and create fusion interactions. Increasing the confinement time of virtual cathode electrons is of critical importance in the performance of polywell reactors. In this paper, COMSOL Multiphysics software was used to perform a three-dimensional numerical simulation in order to investigate the impacts of effective variables of a polywell on the virtual cathode. The findings indicated that the confinement time depends on the distance between the coils, coil radius, coil current, and the kinetic energy of the injected electrons. In addition, by using the simulation results, the dependence of the mentioned parameters on the confinement time is obtained, and then a mathematical model was developed.

Keywords