EJNMMI Radiopharmacy and Chemistry (Nov 2020)

Cyclotron-based production of 68Ga, [68Ga]GaCl3, and [68Ga]Ga-PSMA-11 from a liquid target

  • Melissa E. Rodnick,
  • Carina Sollert,
  • Daniela Stark,
  • Mara Clark,
  • Andrew Katsifis,
  • Brian G. Hockley,
  • D. Christian Parr,
  • Jens Frigell,
  • Bradford D. Henderson,
  • Monica Abghari-Gerst,
  • Morand R. Piert,
  • Michael J. Fulham,
  • Stefan Eberl,
  • Katherine Gagnon,
  • Peter J. H. Scott

DOI
https://doi.org/10.1186/s41181-020-00106-9
Journal volume & issue
Vol. 5, no. 1
pp. 1 – 18

Abstract

Read online

Abstract Purpose To optimize the direct production of 68Ga on a cyclotron, via the 68Zn(p,n)68Ga reaction using a liquid cyclotron target. We Investigated the yield of cyclotron-produced 68Ga, extraction of [68Ga]GaCl3 and subsequent [68Ga]Ga-PSMA-11 labeling using an automated synthesis module. Methods Irradiations of a 1.0 M solution of [68Zn]Zn(NO3)2 in dilute (0.2–0.3 M) HNO3 were conducted using GE PETtrace cyclotrons and GE 68Ga liquid targets. The proton beam energy was degraded to a nominal 14.3 MeV to minimize the co-production of 67Ga through the 68Zn(p,2n)67Ga reaction without unduly compromising 68Ga yields. We also evaluated the effects of varying beam times (50–75 min) and beam currents (27–40 μA). Crude 68Ga production was measured. The extraction of [68Ga]GaCl3 was performed using a 2 column solid phase method on the GE FASTlab Developer platform. Extracted [68Ga]GaCl3 was used to label [68Ga]Ga-PSMA-11 that was intended for clinical use. Results The decay corrected yield of 68Ga at EOB was typically > 3.7 GBq (100 mCi) for a 60 min beam, with irradiations of [68Zn]Zn(NO3)2 at 0.3 M HNO3. Target/chemistry performance was more consistent when compared with 0.2 M HNO3. Radionuclidic purity of 68Ga was typically > 99.8% at EOB and met the requirements specified in the European Pharmacopoeia ( 50% (~ 1.85 GBq, 50 mCi); yields improved as processes were optimized. Labeling yields for [68Ga]Ga-PSMA-11 were near quantitative (~ 1.67 GBq, 45 mCi) at EOS. Cyclotron produced [68Ga]Ga-PSMA-11 underwent full quality control, stability and sterility testing, and was implemented for human use at the University of Michigan as an Investigational New Drug through the US FDA and also at the Royal Prince Alfred Hospital (RPA). Conclusion Direct cyclotron irradiation of a liquid target provides clinically relevant quantities of [68Ga]Ga-PSMA-11 and is a viable alternative to traditional 68Ge/68Ga generators.

Keywords