Sensors (Aug 2010)

High Accuracy Acoustic Relative Humidity Measurement inDuct Flow with Air

  • Cees van der Geld,
  • Twan Wernaart,
  • Mart Grooten,
  • Wilhelm van Schaik

DOI
https://doi.org/10.3390/s100807421
Journal volume & issue
Vol. 10, no. 8
pp. 7421 – 7433

Abstract

Read online

An acoustic relative humidity sensor for air-steam mixtures in duct flow is designed and tested. Theory, construction, calibration, considerations on dynamic response and results are presented. The measurement device is capable of measuring line averaged values of gas velocity, temperature and relative humidity (RH) instantaneously, by applying two ultrasonic transducers and an array of four temperature sensors. Measurement ranges are: gas velocity of 0–12 m/s with an error of ±0.13 m/s, temperature 0–100 °C with an error of ±0.07 °C and relative humidity 0–100% with accuracy better than 2 % RH above 50 °C. Main advantage over conventional humidity sensors is the high sensitivity at high RH at temperatures exceeding 50 °C, with accuracy increasing with increasing temperature. The sensors are non-intrusive and resist highly humid environments.

Keywords