Scientific Reports (Nov 2020)

Radiation pressure measurement using a macroscopic oscillator in an ambient environment

  • Mikko Partanen,
  • Hyeonwoo Lee,
  • Kyunghwan Oh

DOI
https://doi.org/10.1038/s41598-020-77295-5
Journal volume & issue
Vol. 10, no. 1
pp. 1 – 8

Abstract

Read online

Abstract In contrast to current efforts to quantify the radiation pressure of light using nano-micromechanical resonators in cryogenic conditions, we proposed and experimentally demonstrated the radiation pressure measurement in ambient conditions by utilizing a macroscopic mechanical longitudinal oscillator with an effective mass of the order of 20 g. The light pressure on a mirror attached to the oscillator was recorded in a Michelson interferometer and results showed, within the experimental accuracy of 3.9%, a good agreement with the harmonic oscillator model without free parameters.