Energies (Jan 2020)

Comparative Analysis of High Frequency Signal Injection Based Torque Estimation Methods for SPMSM, IPMSM and SynRM

  • Maria Martinez,
  • David Reigosa,
  • Daniel Fernandez,
  • Fernando Briz

DOI
https://doi.org/10.3390/en13030592
Journal volume & issue
Vol. 13, no. 3
p. 592

Abstract

Read online

Torque estimation in permanent magnet synchronous machines and synchronous reluctance machines is required in many applications. Torque produced by a permanent magnet synchronous machine depends on the permanent magnets’ flux and d q -axes inductances, whereas torque in synchronous reluctance machines depends on the d q -axes inductances. Consequently, precise knowledge of these parameters is required for proper torque estimation. The use of high frequency signal both for permanent magnets’ flux and d q -axes inductances estimation has been recently shown to be a viable option. This paper reviews the physical principles, implementation and performance of high-frequency signal injection based torque estimation for permanent magnet synchronous machines and synchronous reluctance machines.

Keywords