Journal of Cardiovascular Magnetic Resonance (Jun 2021)

Cardiovascular magnetic resonance for the detection of descending thoracic aorta calcification in patients with end-stage renal disease

  • Elbert Edy,
  • Alastair J. Rankin,
  • Jennifer S. Lees,
  • Pauline Hall Barrientos,
  • Rosemary Woodward,
  • Sokratis Stoumpos,
  • Ioannis Koktzoglou,
  • Robert R. Edelman,
  • Aleksandra Radjenovic,
  • Patrick B. Mark,
  • Giles H. Roditi

DOI
https://doi.org/10.1186/s12968-021-00769-6
Journal volume & issue
Vol. 23, no. 1
pp. 1 – 11

Abstract

Read online

Abstract Background Vascular calcification is an independent predictor of cardiovascular disease in patients with chronic kidney disease. Computed tomography (CT) is the gold-standard for detecting vascular calcification. Radial volumetric-interpolated breath-hold examination (radial-VIBE), a free-breathing gradient-echo cardiovascular magnetic resonance (CMR) sequence, has advantages over CT as it is ionising radiation-free. However, its capability in detecting thoracic aortic calcification (TAC) has not been investigated. This study aims to compare radial-VIBE to CT for the detection of TAC in the descending aorta of patients with end-stage renal disease (ESRD) using semi-automated methods, and to investigate the association between TAC and coronary artery calcification (CAC). Methods Paired cardiac CT and radial-VIBE CMR scans from ESRD patients participating in 2 prospective studies were obtained. Calcification volume was quantified using semi-automated methods in a 9 cm segment of the thoracic aorta. Correlation and agreement between TAC volume measured on CMR and CT were assessed with Spearman’s correlation coefficient (ρ), linear regression, Bland–Altman plots and intraclass correlation coefficient (ICC). Association between CAC Agatston score and TAC volume determined by CT and CMR was measured with Spearman’s correlation coefficient. Results Scans from 96 participants were analysed. Positive correlation was found between CMR and CT calcification volume [ρ = 0.61, 95% confidence interval (CI) 0.45–0.73]. ICC for consistency was 0.537 (95% CI 0.378–0.665). Bland–Altman plot revealed that compared to CT, CMR volumes were systematically higher at low calcification volume, and lower at high calcification volume. CT did not detect calcification in 41.7% of participants, while radial-VIBE CMR detected signal which the semi-quantitative algorithm reported as calcification in all of those individuals. Instances of suboptimal radial-VIBE CMR image quality were deemed to be the major contributors to the discrepancy. Correlations between CAC Agatston score and TAC volume measured by CT and CMR were ρ = 0.404 (95% CI 0.214–0.565) and ρ = 0.211 (95% CI 0.008–0.396), respectively. Conclusion Radial-VIBE CMR can detect TAC with strong positive association to CT, albeit with the presence of proportional bias. Quantification of vascular calcification by radial-VIBE remains a promising area for future research, but improvements in image quality are necessary.

Keywords