Journal of Engineering and Sustainable Development (Sep 2008)

Comparison between Oil and Water System Due to Power Failure in Pumping Station

  • Muhammad Asmail Eleiwi

Journal volume & issue
Vol. 12, no. 3

Abstract

Read online

In this paper, the power failure in a pumping system has been studied for different flow (Water and Oil). The transient flow rate and head of water and oil had been calculated at different section and effect of fluid properties had been studied. A computer program (Oil Hammer) was developed to solve the mathematical model using predictor-corrector scheme of characteristic methods.

Keywords