Advances in Electrical and Electronic Engineering (Jan 2015)

Behavior of AC High Voltage Polyamide Insulators: Evolution of Leakage Current in Different Surface Conditions

  • Mohammed El Amine Slama,
  • Abderrahmane Beroual

DOI
https://doi.org/10.15598/aeee.v13i2.1145
Journal volume & issue
Vol. 13, no. 2
pp. 74 – 80

Abstract

Read online

This paper is aimed at a systematic study of the leakage current of high voltage polyamide insulator string under different conditions of pollution for possible application in the electric locomotive systems. It is shown that in the case of clean/dry and clean/wetted insulators, the leakage current and applied voltage are linear. While in the case of pollution with saline spray, the leakage current and the applied voltage are not linear; the leakage current changes from a linear regime to a nonlinear regime up to total flashover of the insulators sting. Traces of erosion and tracking of insulators resulting of partial discharges are observed.

Keywords