Građevinski Materijali i Konstrukcije (Jan 2016)

Calibration of the bolt pretension by strain gauges vs. FEA

  • Fric Nenad,
  • Pavlović Marko,
  • Buđevac Dragan,
  • Mišković Zoran,
  • Marković Zlatko,
  • Gluhović Nina

DOI
https://doi.org/10.5937/grmk1604003F
Journal volume & issue
Vol. 59, no. 4
pp. 3 – 15

Abstract

Read online

When applying high strength bolts in friction connections, a load-bearing capacity depends on pretension force in the bolts as well as on friction coefficient found on friction surfaces. It is important to get the reliable value of the pretension force, so friction connections often undergo experimental research. In order to use strain gauges, which are inserted into the bolt shank, bolts need to be calibrated before we even use them in experimental research. Research that has been conducted shows a great difference between nominal and experimental strain in bolts, therefore FEA calibration of the bolts had to be carried out. Good results matching were obtained, hence a use of strain gauges was justified even for bolts without a shank.