Development and validation of a clinical diagnostic model for myocardial ischaemia in borderline coronary lesions based on optical pumped magnetometer magnetocardiography: a prospective observational cohort study
Feng Xu,
Min Zhang,
Xue Yao Yang,
Huan Zhang,
Xin Zhao,
Shu Zhou,
Xiantao Song,
Zhao Ma,
Hong-jia Zhang,
Shuwen Yang,
Lanxin Feng,
Mingduo Zhang,
YaZhe Zhang,
Linqi Liu,
Jiqiang He,
Yanlong Ren,
Yawei Luo,
Chenchen Tu
Affiliations
Feng Xu
Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, 2 Anzhen Road, Chaoyang District, Beijing, China
Min Zhang
Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, 2 Anzhen Road, Chaoyang District, Beijing, China
Xue Yao Yang
Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, 2 Anzhen Road, Chaoyang District, Beijing, China
Huan Zhang
Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, 2 Anzhen Road, Chaoyang District, Beijing, China
Xin Zhao
Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, 2 Anzhen Road, Chaoyang District, Beijing, China
Shu Zhou
Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, 2 Anzhen Road, Chaoyang District, Beijing, China
Xiantao Song
Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, 2 Anzhen Road, Chaoyang District, Beijing, China
Zhao Ma
Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, 2 Anzhen Road, Chaoyang District, Beijing, China
Hong-jia Zhang
4 Department of Cardiovascular Surgery, Beijing Anzhen Hospital, Capital Medical University, Beijing, China
Shuwen Yang
Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, 2 Anzhen Road, Chaoyang District, Beijing, China
Lanxin Feng
Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, 2 Anzhen Road, Chaoyang District, Beijing, China
Mingduo Zhang
Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, 2 Anzhen Road, Chaoyang District, Beijing, China
YaZhe Zhang
Department of Cardiac Surgery, Beijing Anzhen Hospital, Capital Medical University, 2 Anzhen Road, Chaoyang District, Beijing, China
Linqi Liu
Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, 2 Anzhen Road, Chaoyang District, Beijing, China
Jiqiang He
Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, 2 Anzhen Road, Chaoyang District, Beijing, China
Yanlong Ren
Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, 2 Anzhen Road, Chaoyang District, Beijing, China
Yawei Luo
Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, 2 Anzhen Road, Chaoyang District, Beijing, China
Chenchen Tu
Department of Cardiology, Beijing Anzhen Hospital, Capital Medical University, 2 Anzhen Road, Chaoyang District, Beijing, China
Objectives To develop and validate a clinical diagnostic model based on optical pumped magnetometer magnetocardiography (OPM-MCG) for the detection of myocardial ischaemia in patients with borderline coronary lesions prior to invasive coronary angiography (ICA).Design Prospective observational cohort study.Setting Single centre of the China National Clinical Research Centre for Cardiovascular Disease (NCCMRC).Participants Adults with borderline coronary lesions on ICA (n=141).Interventions Underwent OPM-MCG before ICA and fractional flow reserve measurement.Results Five parameters were included in the final diagnostic model: MAgmax-TT, δDtsum-PN, δAgsum-C, δArsum-N and δArmin-N. 1000 bootstrap replications showed that the area under the receiver operating characteristic curve and 95% CI of the diagnostic model were 0.864 (0.803–0.925), with a sensitivity of 79.4%, specificity of 80.8%, positive predictive value of 79.4% and negative predictive value of 80.8%. Decision curve analysis showed a net benefit from the predictive model when the threshold probability of an ischaemic patient was >12%, suggesting the potential utility of the model in the real world.Conclusions A nomogram based on five OPM-MCG parameters was developed to assess myocardial ischaemia in patients with borderline coronary lesions and has the potential to reduce the need for unnecessary ICA.Trial registration number China Clinical Trial Registry (ChiCTR2300072382).