Annals of the University of Oradea: Fascicle of Textiles, Leatherwork (May 2014)
RESEARCHES REGARDING USE OF TEXTILE MATERIALS FOR THERMAL INSULATION AT NEGATIVE TEMPERATURES
Abstract
Using thermal insulation in negative temperature acts to reduce heat flow to the cooled space or to objects that have a temperature below ambient temperature. To achieve economic operation of the space to be cooled insulation thickness and quality is an important factor. In this article we want to compare three products used in thermal insulation at negative temperatures: expanded polystyrene, non-woven and wool coats. The materials will be tested with a mechanical vapor compression refrigerator capable of producing temperatures in the range +4 .. -35 ° C, managed by a programmer Dixel capable of recording values between +40. .. -60 °C. Refrigeration insulation enclosure was made with 100 mm expanded polystyrene. On one side of the enclosure will be a cut of 250 * 250 mm, chosen in a central position where the material will be introduced to be tested. The dimensions of the samples are 250 * 250 * 60 mm. To check the insulation properties of materials it will be used a temperature logger capable of recording with two probes temperatures between +125...-40° C. One of the probes will be inserted inside the refrigerator and the second probe will be positioned to the outside of the test material adhered to an aluminum plate, in order to read a average temperature. The difference in thickness of the insulation shall be filled with non-woven material. Hardening the assembly will be made using a 6 mm thick OSB board. The materials will be tested in an identical ambient temperature and humidity.