Sensors (Oct 2017)

Monitoring Bridge Dynamic Responses Using Fiber Bragg Grating Tiltmeters

  • Feng Xiao,
  • Gang S. Chen,
  • J. Leroy Hulsey

DOI
https://doi.org/10.3390/s17102390
Journal volume & issue
Vol. 17, no. 10
p. 2390

Abstract

Read online

In bridge health monitoring, tiltmeters have been used for measuring rotation and curvature; however, their application in dynamic parameter identification has been lacking. This study installed fiber Bragg grating (FBG) tiltmeters on the bearings of a bridge and monitored the dynamic rotational angle. The dynamic features, including natural frequencies and mode shapes, have been identified successfully. The innovation presented in this paper is the first-time use of FBG tiltmeter readings to identify the natural frequencies of a long-span steel girder bridge. The identified results have been verified using a bridge finite element model. This paper introduces a new method for the dynamic monitoring of a bridge using FBG tiltmeters. Limitations and future research directions are also discussed in the conclusion.

Keywords