Siriraj Medical Journal (Jan 2007)

Rapid Determination of Nevirapine in Human Plasma by High- Performance Liquid Chromatography

  • Kantima Sangsiriwut,
  • Thanomsak Anekthananon,
  • Winai Ratanasuwan,
  • Wichai Techasathit,
  • Surapol Suwanagool,
  • Surin Khunyok,
  • Teera Kolladarungkri

Journal volume & issue
Vol. 59, no. 1

Abstract

Read online

Objective: To develop and validate a high-performance liquid chromatography (HPLC) method for the determination of nevirapine in human plasma. Methods: A plasma sample and an internal standard were extracted with tert-butyl methyl ether and determined nevirapine concentration by HPLC method. The limit of quantitation (LOQ), accuracy, precision, specificity, stability and recovery were tested for method validation. Results: Standard curve was linear in the range 0.1 μg/mL to 20 μg/mL. The limit of quantitation was 0.1 μg/ml. Coefficients of variation (CV) of intra-day and inter-day precision were less than 4%. Accuracy was range from 97-101%. The extraction recovery was range from 94-112%. Conclusion: A rapid, sensitive and specific HPLC method was developed and can be used for determination of plasma nevirapine concentration in adult and pediatric patients infected with HIV.

Keywords