Buildings (Feb 2023)

Seismic Retrofitting of Mid-Rise Unreinforced Masonry Residential Buildings after the 2010 Kraljevo, Serbia Earthquake: A Case Study

  • Predrag Blagojević,
  • Svetlana Brzev,
  • Radovan Cvetković

DOI
https://doi.org/10.3390/buildings13030597
Journal volume & issue
Vol. 13, no. 3
p. 597

Abstract

Read online

There is a significant building stock of post-WWII low- and mid-rise unreinforced masonry (URM) buildings in Serbia and the region (former Yugoslavia). Numerous buildings of this typology collapsed due to the devastating 1963 Skopje, Yugoslavia earthquake, causing fatalities, injuries, and property losses, as well as experienced damage in a few recent earthquakes in the region, including the 2010 Kraljevo, Serbia earthquake (MW 5.5) and the 2020 Petrinja, Croatia earthquake (M 6.4). These buildings are three- to five-stories high, have clay brick masonry walls, and rigid floor slabs, usually with an RC ring beam at each floor level. This paper presents a case study of a URM building which was damaged due to the 2010 Kraljevo earthquake and subsequently retrofitted. A comparison of seismic analysis results, including the capacity/demand ratio and displacement/drift values, for the original and retrofitted building according to the seismic design and retrofit codes which were followed in Serbia as well as some of the neighboring countries for several decades and Eurocode 8 has been presented. The results of this study show that the selected retrofit solution that satisfied the Yugoslav seismic code requirements is not adequate according to the Eurocode 8, primarily due to significantly higher seismic demand.

Keywords