MATEC Web of Conferences (Jan 2018)

Influence of selected cycle components parameters on the supercritical CO2 power unit performance

  • Wołowicz Marcin,
  • Milewski Jarosław,
  • Ziembicki Gabriel

DOI
https://doi.org/10.1051/matecconf/201824005035
Journal volume & issue
Vol. 240
p. 05035

Abstract

Read online

The paper presents the influence of selected components parameters on the performance of supercritical carbon dioxide power unit. For this analysis mathematical model of supercritical recompression Brayton cycle was created. The analysis took into consideration changes in the net cycle power and efficiency for different compressor inlet temperatures. The results were obtained for a fixed minimum pressure of 7.4 MPa and fixed recompression split ratio. The studies conducted in this paper included also consideration of sensitivity of the cycle efficiency to a change in recuperators heat transfer area. In order to determine how each recuperator influences the cycle performance, an analysis of efficiency dependence on the recuperators area was made. Another parameters that were investigated are to a change in turbine and compressors isentropic efficiency and their influence on the cycle efficiency. In the reference cycle, isentropic efficiencies were set up as 88% for both the main and recompression compressor, and 90% for the turbine. Since isentropic efficiency is a sort of measure of broadly defined quality of a turbine or compressor, including airfoil shape, sealing, etc., it may be a significant cost factor that should be considered during cycle design. Therefore, a sensitivity analysis of cycle efficiency to both compressors and turbine isentropic efficiencies was conducted.