Military Medical Research (Jun 2021)

Bioelectrical impedance analysis-guided fluid management promotes primary fascial closure after open abdomen: a randomized controlled trial

  • Kai Wang,
  • Shi-Long Sun,
  • Xin-Yu Wang,
  • Cheng-Nan Chu,
  • Ze-Hua Duan,
  • Chao Yang,
  • Bao-Chen Liu,
  • Wei-Wei Ding,
  • Wei-Qin Li,
  • Jie-Shou Li

DOI
https://doi.org/10.1186/s40779-021-00329-0
Journal volume & issue
Vol. 8, no. 1
pp. 1 – 12

Abstract

Read online

Abstract Background Fluid overload (FO) after resuscitation is frequent and contributes to adverse outcomes among postinjury open abdomen (OA) patients. Bioelectrical impedance analysis (BIA) is a promising tool for monitoring fluid status and FO. Therefore, we sought to investigate the efficacy of BIA-directed fluid resuscitation among OA patients. Methods A pragmatic, prospective, randomized, observer-blind, single-center trial was performed for all trauma patients requiring OA between January 2013 and December 2017 to a national referral center. A total of 140 postinjury OA patients were randomly assigned in a 1:1 ratio to receive either a BIA-directed fluid resuscitation (BIA) protocol that included fluid administration with monitoring of hemodynamic parameters and different degrees of interventions to achieve a negative fluid balance targeting the hydration level (HL) measured by BIA or a traditional fluid resuscitation (TRD) in which clinicians determined the fluid resuscitation regimen according to traditional parameters during 30 days of ICU management. The primary outcome was the 30-day primary fascial closure (PFC) rate. The secondary outcomes included the time to PFC, postoperative 7-day cumulative fluid balance (CFB) and adverse events within 30 days after OA. The Kaplan–Meier method and the log-rank test were utilized for PFC after OA. A generalized linear regression model for the time to PFC and CFB was built. Results A total of 134 patients completed the trial (BIA, n = 66; TRD, n = 68). The BIA patients were significantly more likely to achieve PFC than the TRD patients (83.33% vs. 55.88%, P < 0.001). In the BIA group, the time to PFC occurred earlier than that of the TRD group by an average of 3.66 days (P < 0.001). Additionally, the BIA group showed a lower postoperative 7-day CFB by an average of 6632.80 ml (P < 0.001) and fewer complications. Conclusion Among postinjury OA patients in the ICU, the use of BIA-guided fluid resuscitation resulted in a higher PFC rate and fewer severe complications than the traditional fluid resuscitation strategy.

Keywords